Sizes: 63 mm & 80mm Dial diameter and 100 mm (4”) & 150mm (6") Mounting: Direct, Surface and Flush Case & Bezel: Full Safety Pattern case to S3 standard and Die Cast Scale Ranges: 0 to 600 mbar to 0 to 1400 bar, 0 to 400 mBar up to 0 to 1400 Bar Pressure Element: ≤80 Bar for 316 Stainless Steel Bourdon Tube and ≥81 Bar for 316 Stainless Steel Coil Overload: Up to 130% of FSD Pressure Connection in 316 Stainless Steel: 3/8”, 1/2” BSP and 1/2" NPT Accuracy Class: 1% of FSD (CL1) as defined in EN837-1 (Options available) Operating Temperature: -20 to +90 ºC operating Dial: White Anodised Aluminium marked in black finish Pointer: Stainless steel coloured black Movement: Stainless Steel Construction Window: 3mm Laminated Safety Glass (Standard) Environmental Rating: IP67 as defined in EN 60 529 Traceability: Calibrated with unique Serial Number printed on the dial Certification: BS EN 10204 3.
Germany
This high-precision calibration source is able to measure currents up to ±50 mA, voltages ±100 V and temperature setpoint values of 12 thermocouple types, including R, S, B, J, T, E, K and N. Voltage drops across the measuring leads can be easily compensated via the sense line. With “thermoelectric voltage simulation” you can enter °C, °F and K, the temperature scales ITS-90 or IPTS-68 and the reference junction type constant/external. Furthermore, when simulating thermocouples a calibrated external reference junction can be used, with the calibration data being taken into account in the device. The device can be operated both via the keypad and via the Ethernet and USB interface. Features: — DC voltage up to ±100.0000 V, ±0.002 % — DC current up to ±50.0000 mA, ±0.005 % - Thermocouple simulation of R, S, B, J, T, E, K, N, M, C, D, G2 - Automatic sequence function (ramp function)
Request for a quoteGermany
High-precision angle measuring system with +/-0.1s accuracy for measuring and calibration applications. The signal sampling is done by an interferometric operating principle (laserscale) The graduation period is 1µm, the generated signal period of the output signal is 250nm. Scale errors are self-compensated by using six reading heads in a special arrangement. The measured values can be output in csv format via the USB interface. The software for measured value acquisition and storage is included in the scope of delivery.
Request for a quoteGermany
Bourdon tube pressure gauges Stainless steel, polypropylene or phenolic Wetted parts AISI 316L or monel Dial size: 63 mm,100 mm to 160 mm Ranges from -1...0 to 0...1600 bar Solid front, safety version S3
Request for a quoteCreate one request and get multiple quotes form verified suppliers.