The 8 terminals of the µCAN.8.dio-BOX may individually be set to act as digital inputs or digital outputs. The module preprocesses and filters the digital signals. Its CAN interface supports the protocols CANopen, CANopen FD and J1939.Digital input or output Galvanically isolated fieldbus Input or output freely configurable Each output to be charged with max. 1 A Output drivers can be supplied separately Current measurement per output Status indicator for each input / output Protected against mechanical impact Fieldbus CAN / CAN FD Protocol CANopen / CANopen FD Protocol J1939 / Raw CAN

Request for a quote

Germany

Verified by Europages

At its eight outputs the µCAN.8.pwm-BOX provides pulse width modulated signals (PWM) within a range of 0% to 100% for controlling of actuators (valves etc.). The outlets are overload and short circuit protected. The µCAN.8.pwm-BOX is connected with the central control unit via CAN bus.PWM output Basic frequency 40 Hz … 5 kHz Mark-to-space ratio 0.0 % … 100.0 % Galvanically isolated fieldbus Each output to be charged with max. 1.4 A 3-wire connector terminal Output drivers supplied separately Status indication at each output Protected against mechanical impact Fieldbus CAN Protocol CANopen / Raw CAN

Request for a quote

Germany

Verified by Europages

The µCAN.4.ci-BOX is equipped with 4 fast counters of up to 100 kHz. The CAN module acquires and processes the binary pulses and transmits them to a higher-level systemCounter input / frequency measurement A/B signal Max. input frequency 500 kHz Galvanically isolated fieldbus High precision frequency measurement Signal type freely configurable Up or down counter Protected against mechanical stress Fieldbus CAN Protocol CANopen / RawCAN

Request for a quote

Germany

Verified by Europages

The measurement data acquisition module µCAN.1.ai-SNAP acquires analogue measurement signals and links them to the digital CAN world.Features Voltage +/- 10 V Current 0(4)…20 mA Accuracy 0.01% (FS) Resolution 16-bit (1 mV / 1 µA) Sampling rate 20 ms / 50 Hz Galvanically isolated fieldbus (option) Signal type freely configurable Screw connection via plug-in connectors Fieldbus CAN Protocol CANopen / Raw CAN

Request for a quote

Germany

Verified by Europages

The module µCAN.1.sg-SNAP is designed to acquire strain gauge measurement signals such as forces, torques, sequences and voltages and transfers them via CAN.Strain gauge full bridge Voltage 0…100 mV Supply voltage 9.0 V Accuracy 0.1 % (FS) Resolution 16-bit (1 mV) Sampling rate 20 ms / 50 Hz Galvanically isolated fieldbus (option) Screw connection via plug-in connectors Fieldbus CAN Protocol CANopen / Raw CAN

Request for a quote

Germany

Verified by Europages

The module µCAN.1.ti-SNAP is designed to acquire temperature signals via Pt100 or J, K and L type thermocouples.Temperature Thermo type J, K, L Temperature Pt100, Pt1000 (2- / 4-wire) Accuracy +/- 0.5 K (Thermo) Accuracy +/- 0,1 K (Pt100, Pt1000) Resolution 16-bit (0.1 °C) Sampling rate 20 ms / 50 Hz Galvanically isolated fieldbus (option) Signal type freely configurable Screw connection via plug-in connectors Protocol CAN / CANopen / Raw CAN

Request for a quote

Germany

Verified by Europages

The decentralized module µCAN.6.ai-SNAP is designed to acquire up to 6 analogue current / voltage signals and converts them into digital CAN signals.Voltage +/- 10 V Current 0(4)…20 mA Accuracy 0.02 % (FS) Resolution 16-bit (1 mV / 1 µA) Sampling rate 20 ms / 50 Hz Galvanically isolated fieldbus (option) Screw connection via plug-in connectors Fieldbus CAN Protocol CANopen / Raw CAN

Request for a quote

Germany

Verified by Europages

The transducer unit µCAN.8.ti-SNAP is equipped with 8 inputs for thermocouples or Pt100 sensors. The integrated CAN interface supports CANopen and J1939 protocols. Bit rate and node-ID may be set via DIP switches inside the device or via LSS.Temperature thermo type J, K, L, N, R, T Temperature Pt100/Pt1000 (2-wire) Accuracy +/- 0.5 K (Thermo) Accuracy +/- 0.2 K (Pt100) Resolution 16-bit (0.1 °C) Sampling rate 20 ms / 50 Hz Galvanically isolated fieldbus (option) Sensor error detection Screw connection via plug-in connectors Protocol CAN / CANopen / Raw CAN

Request for a quote

Germany

Verified by Europages

The modul µCAN.4.ao-SNAP features 4 independent analogue outputs which optionally provide a voltage or a current signal. The CAN interface supports CANopen and J1939 protocols.Voltage +/- 10 VCurrent 0…20 mA Accuracy 0.05 % (FS) Resolution 16-bit (1 mV / 1 µA) Signal output 1 ms / 1 kHz Galvanically isolated fieldbus Galvanically isolated analogue outputs Signal type freely configurable Screw connection via plug-in connectors Protocol CANopen / Raw CAN / J1939

Request for a quote

Germany

Verified by Europages

The µCAN.8.dio-SNAP is a freely configurable digital I/O module featuring 8 channels. Module ID and bit rate can be set via DIP switch or via CAN bus (LSS, CiA 305).Digital input or output Galvanically isolated fieldbus (option) Input or output freely configurable Output drivers can be supplied separately Each output to be charged with max. 1 A Push-in connection at the plug-in connectors Fieldbus CAN / CAN FD Protocol CANopen / CANopen FD Protocol J1939 / Raw CAN